2026-02-21 10:01:45 +00:00
|
|
|
|
# Arburg ↔ Thermoplay Hot Runner Wiring
|
2026-02-21 10:05:39 +00:00
|
|
|
|

|
|
|
|
|
|

|
2026-02-21 10:01:45 +00:00
|
|
|
|
|
|
|
|
|
|
> Proportional regulator / Hot runner interface wiring documentation
|
|
|
|
|
|
> Date: 11.11.2023
|
|
|
|
|
|
|
|
|
|
|
|
---
|
|
|
|
|
|
|
|
|
|
|
|
## Overview
|
|
|
|
|
|
|
|
|
|
|
|
This document describes the wiring between the **Arburg machine connectors** and the **Thermoplay hot runner** connector.
|
|
|
|
|
|
⚠️ **Important:** Heater zone pinouts and J-type thermocouple (TC) pinouts use **different pin assignments** on each side.
|
|
|
|
|
|
|
|
|
|
|
|
---
|
|
|
|
|
|
|
|
|
|
|
|
## Thermoplay Connector Pinout (M / F)
|
|
|
|
|
|
|
|
|
|
|
|
From the Thermoplay connector label (Image 2):
|
|
|
|
|
|
|
|
|
|
|
|
| Function | M-side Pin (+) | F-side Pin (-) |
|
|
|
|
|
|
|----------|---------------|----------------|
|
|
|
|
|
|
| ZONE 1 | 1 | 13 |
|
|
|
|
|
|
| ZONE 2 | 2 | 14 |
|
|
|
|
|
|
| ZONE 3 | 3 | 15 |
|
|
|
|
|
|
| ZONE 4 | 4 | 16 |
|
|
|
|
|
|
| ZONE 5 | 5 | 17 |
|
|
|
|
|
|
| ZONE 6 | 6 | 18 |
|
|
|
|
|
|
| TC 1 | 7 (+) | 19 (−) |
|
|
|
|
|
|
| TC 2 | 8 (+) | 20 (−) |
|
|
|
|
|
|
| TC 3 | 9 (+) | 21 (−) |
|
|
|
|
|
|
| TC 4 | 10 (+) | 22 (−) |
|
|
|
|
|
|
| TC 5 | 11 (+) | 23 (−) |
|
|
|
|
|
|
| TC 6 | 12 (+) | 24 (−) |
|
|
|
|
|
|
|
|
|
|
|
|
---
|
|
|
|
|
|
|
|
|
|
|
|
## Arburg Machine Connector Pinout
|
|
|
|
|
|
|
|
|
|
|
|
### Heater Zones (connectors -4X4 / -4X2)
|
|
|
|
|
|
|
|
|
|
|
|
| Arburg Zone | Pin (+) | Pin (−) |
|
|
|
|
|
|
|-------------|---------|---------|
|
|
|
|
|
|
| Heater 1 | 1 | 2 |
|
|
|
|
|
|
| Heater 2 | 3 | 4 |
|
|
|
|
|
|
| Heater 3 | 5 | 6 |
|
|
|
|
|
|
| Heater 4 | 7 | 8 |
|
|
|
|
|
|
| Heater 5 | 9 | 10 |
|
|
|
|
|
|
| Heater 6 | 11 | 12 |
|
|
|
|
|
|
|
|
|
|
|
|
> Each heater zone uses a **pair of adjacent pins** (odd = +, even = −).
|
|
|
|
|
|
|
|
|
|
|
|
---
|
|
|
|
|
|
|
|
|
|
|
|
### Thermocouple Inputs — J-Type (connectors -4X3 / -4X1)
|
|
|
|
|
|
|
|
|
|
|
|
| Arburg TC | Pin (+) | Pin (−) |
|
|
|
|
|
|
|-----------|---------|---------|
|
|
|
|
|
|
| TC 1 | 13 | 14 |
|
|
|
|
|
|
| TC 2 | 15 | 16 |
|
|
|
|
|
|
| TC 3 | 17 | 18 |
|
|
|
|
|
|
| TC 4 | 19 | 20 |
|
|
|
|
|
|
| TC 5 | 21 | 22 |
|
|
|
|
|
|
| TC 6 | 23 | 24 |
|
|
|
|
|
|
|
|
|
|
|
|
> TC signals are **J-type thermocouples**. Polarity must be respected — reversed polarity will cause incorrect temperature readings.
|
|
|
|
|
|
|
|
|
|
|
|
---
|
|
|
|
|
|
|
|
|
|
|
|
## Cross-Wiring Table: Arburg → Thermoplay
|
|
|
|
|
|
|
|
|
|
|
|
| Signal | Arburg Pin | Thermoplay Pin |
|
|
|
|
|
|
|----------|-----------|----------------|
|
|
|
|
|
|
| Zone 1 + | 1 | 1 |
|
|
|
|
|
|
| Zone 1 − | 2 | 13 |
|
|
|
|
|
|
| Zone 2 + | 3 | 2 |
|
|
|
|
|
|
| Zone 2 − | 4 | 14 |
|
|
|
|
|
|
| Zone 3 + | 5 | 3 |
|
|
|
|
|
|
| Zone 3 − | 6 | 15 |
|
|
|
|
|
|
| Zone 4 + | 7 | 4 |
|
|
|
|
|
|
| Zone 4 − | 8 | 16 |
|
|
|
|
|
|
| Zone 5 + | 9 | 5 |
|
|
|
|
|
|
| Zone 5 − | 10 | 17 |
|
|
|
|
|
|
| Zone 6 + | 11 | 6 |
|
|
|
|
|
|
| Zone 6 − | 12 | 18 |
|
|
|
|
|
|
| TC 1 + | 13 | 7 |
|
|
|
|
|
|
| TC 1 − | 14 | 19 |
|
|
|
|
|
|
| TC 2 + | 15 | 8 |
|
|
|
|
|
|
| TC 2 − | 16 | 20 |
|
|
|
|
|
|
| TC 3 + | 17 | 9 |
|
|
|
|
|
|
| TC 3 − | 18 | 21 |
|
|
|
|
|
|
| TC 4 + | 19 | 10 |
|
|
|
|
|
|
| TC 4 − | 20 | 22 |
|
|
|
|
|
|
| TC 5 + | 21 | 11 |
|
|
|
|
|
|
| TC 5 − | 22 | 23 |
|
|
|
|
|
|
| TC 6 + | 23 | 12 |
|
|
|
|
|
|
| TC 6 − | 24 | 24 |
|
|
|
|
|
|
|
|
|
|
|
|
---
|
|
|
|
|
|
|
|
|
|
|
|
## Key Differences — Arburg vs Thermoplay
|
|
|
|
|
|
|
|
|
|
|
|
| Property | Arburg Side | Thermoplay Side |
|
|
|
|
|
|
|-------------------|-------------------------------------|------------------------------------|
|
|
|
|
|
|
| Heater pair logic | Adjacent pins (1+2, 3+4, …) | Split across M/F halves (1/13, 2/14, …) |
|
|
|
|
|
|
| TC logic | Sequential pairs (13+14, 15+16, …) | Offset by 12 pins (7/19, 8/20, …) |
|
|
|
|
|
|
| TC type | J-type | J-type |
|
|
|
|
|
|
| Zones supported | Up to 6 | Up to 6 |
|
|
|
|
|
|
|
|
|
|
|
|
---
|
|
|
|
|
|
|
|
|
|
|
|
## Notes
|
|
|
|
|
|
|
|
|
|
|
|
- Always verify wiring with a multimeter before powering up.
|
|
|
|
|
|
- Mislabelled or swapped TC wires will cause **temperature runaway** or zone shutdown.
|
|
|
|
|
|
- Heater zones carry **mains voltage** — ensure the machine is **locked out** before working on wiring.
|
|
|
|
|
|
- Module references from schematic: `-4X1`, `-4X2`, `-4X3`, `-4X4`
|
|
|
|
|
|
|
|
|
|
|
|
---
|
|
|
|
|
|
|
|
|
|
|
|
*Document generated from Arburg proportional regulator schematic & Thermoplay connector diagram.*
|