Update readme.md
This commit is contained in:
parent
2f550b8794
commit
3b3ffcd8aa
|
|
@ -39,7 +39,7 @@ From the Thermoplay connector label (Image 2):
|
||||||
|
|
||||||
### Heater Zones (connectors -4X4 / -4X2)
|
### Heater Zones (connectors -4X4 / -4X2)
|
||||||
|
|
||||||
| Arburg Zone | Pin (+) | Pin (−) |
|
| Arburg Zone | Pin (L) | Pin (N) |
|
||||||
|-------------|---------|---------|
|
|-------------|---------|---------|
|
||||||
| Heater 1 | 1 | 2 |
|
| Heater 1 | 1 | 2 |
|
||||||
| Heater 2 | 3 | 4 |
|
| Heater 2 | 3 | 4 |
|
||||||
|
|
@ -48,11 +48,11 @@ From the Thermoplay connector label (Image 2):
|
||||||
| Heater 5 | 9 | 10 |
|
| Heater 5 | 9 | 10 |
|
||||||
| Heater 6 | 11 | 12 |
|
| Heater 6 | 11 | 12 |
|
||||||
|
|
||||||
> Each heater zone uses a **pair of adjacent pins** (odd = +, even = −).
|
> Each heater zone uses a **pair of adjacent pins**.
|
||||||
|
|
||||||
---
|
---
|
||||||
|
|
||||||
### Thermocouple Inputs — J-Type (connectors -4X3 / -4X1)
|
### Thermocouple Inputs —
|
||||||
|
|
||||||
| Arburg TC | Pin (+) | Pin (−) |
|
| Arburg TC | Pin (+) | Pin (−) |
|
||||||
|-----------|---------|---------|
|
|-----------|---------|---------|
|
||||||
|
|
@ -114,7 +114,6 @@ From the Thermoplay connector label (Image 2):
|
||||||
- Always verify wiring with a multimeter before powering up.
|
- Always verify wiring with a multimeter before powering up.
|
||||||
- Mislabelled or swapped TC wires will cause **temperature runaway** or zone shutdown.
|
- Mislabelled or swapped TC wires will cause **temperature runaway** or zone shutdown.
|
||||||
- Heater zones carry **mains voltage** — ensure the machine is **locked out** before working on wiring.
|
- Heater zones carry **mains voltage** — ensure the machine is **locked out** before working on wiring.
|
||||||
- Module references from schematic: `-4X1`, `-4X2`, `-4X3`, `-4X4`
|
|
||||||
|
|
||||||
---
|
---
|
||||||
|
|
||||||
|
|
|
||||||
Loading…
Reference in a new issue