Compare commits
3 commits
dejan-patc
...
main
| Author | SHA1 | Date | |
|---|---|---|---|
|
|
e9be9c6bb3 | ||
|
|
736e82f521 | ||
|
|
afdf929ee6 |
16
readme.md
16
readme.md
|
|
@ -15,6 +15,14 @@ This document describes the wiring between the **Arburg machine connectors** and
|
|||
---
|
||||
|
||||
## Thermoplay Connector Pinout (M / F)
|
||||
|
||||
| Connector | Part number + comment |
|
||||
|-----------|-----------------------|
|
||||
|09330242601| Han E 24 Pos. M Insert Screw|
|
||||
|09330242701| Han E 24 Pos. F Insert Screw|
|
||||
|
||||
|
||||
|
||||

|
||||

|
||||
From the Thermoplay connector label (Image 2):
|
||||
|
|
@ -116,6 +124,12 @@ Connection scheme for a typical dual-zone heating system with two heaters and tw
|
|||
|
||||
## Pinout / Terminal Layout - 8PIN connector 7+PE
|
||||
|
||||
| Connector | Part number + comment |
|
||||
|-----------|-----------------------|
|
||||
|09 36 008 2632| Han 8D-M Quick Lock 1,5mm²|
|
||||
|09 36 008 2732| Han 8D-F Quick Lock 1,5mm²|
|
||||
|
||||
|
||||
| PIN | OZNAKA / Signal | Description | Typical Wire Color (Type K) |
|
||||
|-------|-----------------------|------------------------------|-----------------------------|
|
||||
| 1 | Grelec 1 | Heater 1 – Live / Phase | – |
|
||||
|
|
@ -127,6 +141,8 @@ Connection scheme for a typical dual-zone heating system with two heaters and tw
|
|||
| 7 | Grelec 2 | Heater 2 – Neutral / Return | – |
|
||||
| 8/PE | Termočlen 2- | Thermocouple 2 – Negative | White / Red |
|
||||
|
||||

|
||||
|
||||
**Notes:**
|
||||
|
||||
- Pins 1 & 5 → Heater 1 (usually 230 V AC or 24 V, depending on system)
|
||||
|
|
|
|||